Specifications
| A&D LCB04K250L Single-point load cell LCB04K250L |
| Specifications: Single-point load cell LCB04K250L |
| Rated capacity (kN): 2.5kN (254.9kg) |
| Recommended applied voltage (V): DC 5-12 |
| Overall error: 0.02% of R.O. |
| Maximum overload: 200% of R.C. |
| Allowable overload: 150% of R.C. |
| Rated output: 2mV/V ±10% |
| Maximum applied voltage (V): DC 15 |
| Zero balance: ±5% of R.O. |
| Weight: 0.47kg |
| Set contents/Accessories: Instruction manual |
| Country of origin: Japan |
Note: For US buyers, import duties are included in the price. For buyers outside the US, import duties are not included in the price.